RGII gas fire rules and Declaration of Conformance
Every natural gas or LPG fire installed, altered or disconnected in Ireland must be handled by a Registered Gas Installer (RGI) working to I.S. 813. On handover you must receive the signed, numbered Declaration of Conformance confirming gas soundness, operating pressure and flue spillage tests.
Why every natural gas or LPG fire installation, repair or disconnection in Ireland legally requires an RGI under I.S. 813.
Free, no obligation. One local installer prices it, not five.
- I.S. 813Irish domestic gas standard
- Legal ruleRGI mandatory for gas & LPG
- €500–€1,100RGII fit & certification
- €180–€350RGI gas line disconnection

What the law requires on every domestic gas fireplace
Under the Commission for Regulation of Utilities (CRU) regulatory framework, working on domestic natural gas or LPG pipework and appliances without active registration on the Register of Gas Installers of Ireland is a criminal offence. Even seemingly simple tasks, such as unhooking an old coal-effect gas fire so a builder can fit a marble surround, legally require an RGI to purge and cap the line safely.
- Check the RGI photo ID card and register number. Confirm the installer is active on rgii.ie before gas pipework starts.
- Gas tightness and burner pressure verification. The RGI manometer-tests the domestic gas installation for leaks before and after fitting, confirming correct working pressure at full load.
- Flue flow and spillage testing under I.S. 813. Conventional flued gas fires undergo smoke-match spillage testing with extractor fans running; balanced-flue kits are checked for airtight concentric seals and legal exterior terminal clearances.
- Receive the white householder Declaration of Conformance. This numbered safety certificate proves I.S. 813 compliance for home insurance, appliance warranties and property sales.
Price my fireplace
Four taps reveal an Irish fireplace guide before any phone number is requested. One local installer rings you, not five.
An RGII gas fire and fireplace surround with a balanced flue on an outside wall, supplied and fitted: €2,900 to €5,800.
How these fireplace figures are worked out
Supply-and-fit bands reflect typical Irish pricing for marble, Portuguese limestone, cast-iron, gas or solid-fuel suites fitted into a sound opening, including bedding the hearth and sealing slips. Gas options allow for an RGII installer, soundness testing and a Declaration of Conformance. Fit-only figures cover skilled installation labour, hearth slabbing and making good when you supply your own mantel and hearth. Old back-boiler plumbing removal, structural RSJ beams, chimney relining and bespoke plastering depend on what lies behind the plaster and are priced once inspected.
Balanced-flue external terminal clearances under I.S. 813
- Clear of opening windows and doors. External balanced-flue terminals must maintain minimum horizontal and vertical distances from windows, air bricks and eaves so exhaust gases never re-enter the house.
- Clear of neighbouring boundaries. Exhaust plumes cannot discharge across a boundary fence or narrow side alley onto a neighbour's wall.
- Protective terminal guard below 2 m. Any balanced-flue terminal exiting within 2 m of ground level or a patio walkway requires a purpose-made wire guard to prevent accidental burns.
Explore fitted prices on balanced-flue and conventional gas fires and chimney and flue types.
More Irish fireplace guides
Gas fire installationConventional chimney and outside-wall balanced-flue gas fires certified by an RGI.
Class 1, precast & balanced fluesIdentifying your Irish chimney before ordering a gas or open fire.
Carbon monoxide alarm rulesMandatory I.S. EN 50291 alarms and placement distances under TGD J.
Hole-in-the-wall suitesFrameless recessed gas and linear fireplace suites framed flush in plaster.
Back-boiler & tiled rip-outsDraining legacy pipework, breaking concrete hearths and making walls sound.
Fireplace installation costsComplete Irish supply-and-fit and fit-only price guide by fireplace type.Answers before the hearth goes in
What certificate must I get after a gas fire is fitted in Ireland?
Your installer must hand over a signed, numbered Declaration of Conformance (DOC) confirming the installation complies with I.S. 813.
Can a general fireplace fitter connect a gas fire if they fit the marble surround?
Only if they hold active RGII registration themselves, or partner with a named RGI who connects, tests and certifies the gas appliance separately.
How much does an RGI charge to cap an old gas fire before renovation?
Disconnecting, purging and capping a redundant domestic gas fire supply safely runs €180 to €350.
Does RGII cover bottled LPG gas fires in rural counties?
Yes. Both mains natural gas and domestic LPG cylinder or bulk-tank installations fall under RGII and I.S. 813.