Fireplace Installers in Ireland, Priced by the Fireplace

Pick the surround, fire and chimney setup in your room. See realistic Irish supply-and-fit figures right away. Then one local fireplace installer calls with a written price.

Free, no obligation. One local installer prices it, not five.

  • €1,800 to €4,800full fireplace surround and fire, fitted
  • €550 to €1,100fit-only labour for surround and hearth
  • RGII & Part Jmandatory gas certs and 300 mm hearths
  • 1,836,728occupied private Irish homes, Census 2022

Price my fireplace

Four taps reveal an Irish fireplace guide before any phone number is requested. One local installer rings you, not five.

A marble or limestone fireplace surround into a Class 1 brick chimney, supplied and fitted: €2,100 to €4,400.

Step 1 of 5

What fireplace work do you want priced?

Tap the closest match. The installer checks dimensions in person.

How these fireplace figures are worked out

Supply-and-fit bands reflect typical Irish pricing for marble, Portuguese limestone, cast-iron, gas or solid-fuel suites fitted into a sound opening, including bedding the hearth and sealing slips. Gas options allow for an RGII installer, soundness testing and a Declaration of Conformance. Fit-only figures cover skilled installation labour, hearth slabbing and making good when you supply your own mantel and hearth. Old back-boiler plumbing removal, structural RSJ beams, chimney relining and bespoke plastering depend on what lies behind the plaster and are priced once inspected.

From hearth survey to first lighting in three stages

  1. Build your Irish fireplace estimateTap your stone or fire style, flue setup and whether old masonry is coming out to view realistic figures before sharing a mobile number.
  2. One county installer checks the chimney breastYour brief goes to one installer covering your county, who measures the builders' opening, tests chimney draw and inspects gas or hearth depth.
  3. Bedded, sealed and certified cleanlyHearths are laid with expansion cuts, surrounds pinned flush to the breast, gas lines signed off on an RGII certificate and rubble cleared.

Buying stone blind, or quoting after a flue survey

Buying stone blind

  • Ordering a solid-slab hearth that cracks on the first coal or log fire
  • Discovering a narrow precast flue cannot house a deep inset gas burner
  • Answering five separate sales calls from a shared directory form

Quoting after a flue survey

  • Irish supply-and-fit or fit-only guide shown before you leave a number
  • Hearth depth, fireback condition, RGII gas route and mantel height verified first
  • One local fireplace installer prices stonework, fitting and removal on one sheet

Four checks homeowners ask before booking a survey

Will I be hounded with calls?
No. Your details are sent to a single fireplace installer in your county, and nobody else. Never shared with a call centre or broker list.
Can I supply my own marble surround and book fit-only?
Yes. Fit-only fireplace installation runs €550 to €1,100 for bedding the hearth, pinning the mantel and sealing slips into a prepared opening.
Who is legally allowed to connect a gas fire in Ireland?
Only an active Registered Gas Installer under I.S. 813. On completion they hand over your numbered Declaration of Conformance covering soundness and spillage checks.
Why do granite hearths crack under open solid fuel?
A single unbroken piece of granite expands unevenly under fierce coal or wood heat. Solid-fuel hearths are cut into sections and reinforced underneath with cement and mesh.
Honed cream limestone fireplace surround with stepped mantel, hearth and glowing inset fire on a pale plastered wall

Check your fireplace price before anyone calls

Choose the surround style, chimney situation and supply or fit-only scope. One written quote comes back from a single fireplace installer in your county.

Surround materials compared for Irish sitting rooms

Stone choice sets both visual character and whether the hearth handles solid-fuel expansion safely.

Portuguese limestone

Typical fitted suite
€2,100–€4,200
Heat suitability
Solid fuel, gas or electric
Surface appearance
Warm matte fossils and veins
Care needed
Seal porous stone every few years

Natural marble

Typical fitted suite
€2,800–€5,800
Heat suitability
Solid fuel (slabbed) or gas
Surface appearance
High gloss or honed veining
Care needed
Wipe neutral cleaner; avoid acid

Cast iron & slate

Typical fitted suite
€2,100–€4,400
Heat suitability
Open coal, logs or gas
Surface appearance
Blacked iron or burnished steel
Care needed
Touch with stove polish yearly

Engineered quartz

Typical fitted suite
€1,950–€3,900
Heat suitability
Gas and electric only
Surface appearance
Uniform crisp modern tone
Care needed
Non-porous wipe-clean resin

Every extra line item, from RGII gas fitting and clay firebacks to back-boiler rip-outs, sits on fireplace installation costs in Ireland.

Irish Part J hearth dimensions and safety thresholds

Department of Housing Technical Guidance Document J rules every compliant hearth must satisfy.

125 mmSolid hearth depthOver concrete floor
250 mmOver timber joistsWithout 50 mm air gap
300 mmFront apronIn front of open fire
150 mmSide projectionEach side of opening
  1. 125 mm or 250 mm constructional depth. Non-combustible hearth masonry must reach 125 mm on concrete floors, or 250 mm directly over timber joists unless separated by a 50 mm air gap.
  2. 300 mm front and 150 mm side clearances. Open fires need a non-combustible apron extending at least 300 mm forward of the opening and 150 mm past each jamb.
  3. RGII law on every natural gas or LPG fire. Connecting, relocating or capping gas lines is restricted under I.S. 813 to a Registered Gas Installer issuing a Declaration of Conformance.
  4. Mandatory I.S. EN 50291 carbon monoxide alarm. Any room receiving a new or replacement open-flued combustion fireplace must carry an audible CO alarm, plus cover within 5 m of bedrooms.

Read the full breakdown in Part J hearth and clearance rules, RGII gas fire rules and carbon monoxide alarm rules.

Matching the fire to your chimney breast before ordering

Irish houses built across different decades carry three distinct flue types.

Class 1 brick or block chimney

175 mm+ flue liner

Standard in pre-1970s houses and rural builds; suits open fires, cast-iron grates and conventional gas fires.

Precast narrow cavity flue

Shallow block flue

Built into many 1970s to 2000s Irish estates; too narrow for open logs and needs slimline precast-rated gas fires.

Balanced-flue outside wall

No chimney required

Room-sealed glass-fronted gas fire venting straight through an external gable or rear wall with coaxial pipe.

Check how to tell which stack sits behind your plaster on Class 1, precast and balanced flues in Ireland and builders' openings and sizes.

Local fireplace installers in all 26 counties

Select your county in step 4 so an installer working locally measures the opening and quotes directly.

Natural stone mantels weigh 120 kg to 250 kg in sections and require careful two-person handling, dry-fitting and mortar bedding. Working with an installer based in your own region avoids national haulage surcharges and makes follow-up adjustments simple. Explore Dublin and Leinster fireplaces, Munster and Connacht fireplaces and all 26 counties covered.

Five details to confirm before signing a fireplace quote

Insist on seeing each of these lines itemised in writing.

  • Exact stone and finish named. Portuguese limestone, honed or polished marble, Kilkenny limestone, engineered quartz or cast iron listed clearly.
  • Slabbed hearth specified for solid fuel. Confirm expansion cuts and cement backing on granite or slate hearths burning coal, peat or timber.
  • Part J hearth thickness and projection. Check 125 mm / 250 mm hearth build-up, 300 mm front apron and 150 mm side overhang on open fires.
  • RGII registration and Declaration of Conformance. Mandatory for any natural gas or LPG pipework, balanced-flue coring or old gas capping.
  • Flue sweep and smoke draw test included. Never bed a new marble mantel over an untested chimney or cracked clay fireback.

View all ten checks on fireplace installation costs.

Answers before the hearth goes in

How much does it cost to supply and fit a new fireplace in Ireland?

A complete fireplace surround, hearth and fire supplied and fitted in Ireland typically costs €1,800 to €4,800. Portuguese limestone and marble suites start near €2,100, RGII gas fire packages run €2,400 to €4,600 into an existing chimney or €2,900 to €5,800 with an outside-wall balanced flue, and fit-only surround labour runs €550 to €1,100. Full Irish price breakdown.

How much do fireplace installers charge for fit-only labour?

Expect €550 to €1,100 to fit a customer-supplied marble, limestone or cast-iron surround and slabbed hearth into a ready opening. Removing an old tiled fireplace adds €200 to €450, and RGII gas connection adds €500 to €1,100. Fit-only installation guide.

What hearth dimensions does Part J require in Ireland?

Under Irish Building Regulations Technical Guidance Document J, a solid-fuel fireplace requires a non-combustible constructional hearth at least 125 mm thick (250 mm directly over timber without a 50 mm air gap), projecting at least 300 mm in front of an open fire and 150 mm to each side, plus a certified I.S. EN 50291 carbon monoxide alarm. Read Part J hearth rules.

Is an RGII installer legally required for every gas fire in Ireland?

Every natural gas or LPG fire installed, altered or disconnected in Ireland must be handled by a Registered Gas Installer (RGI) working to I.S. 813. On handover you must receive the signed, numbered Declaration of Conformance confirming gas soundness, operating pressure and flue spillage tests. RGII rules explained.

Can I burn coal or logs inside an engineered quartz fireplace surround?

No. Engineered quartz uses polymer resin binders that scorch, discolour and crack under direct solid-fuel temperatures. Keep quartz surrounds for gas or electric appliances and specify natural marble, Portuguese limestone or slabbed granite for solid fuel. Surround materials compared.

Can you fit a real gas fire if the house has no chimney?

Yes, provided the fireplace sits on an external wall where a balanced-flue coaxial terminal can exit cleanly with I.S. 813 boundary and window clearances. Balanced-flue gas packages run €2,900 to €5,800 supplied and fitted. Gas fire installation.

What does removing an old back-boiler or chimney breast cost?

Draining and ripping out a legacy solid-fuel back boiler and making good runs €650 to €1,400. Taking out a ground-floor chimney breast with steel support runs €1,300 to €2,400, plus €300 to €650 for engineer calculations. Chimney breast removal.

Who rings me after I finish the fireplace planner?

Your fireplace outline and mobile number go straight to a single fireplace installer in your county, and nobody else. They arrange a chimney and wall check and issue a written quote.

Every Irish fireplace guide on this site